Mid-Range Cryogenic Oxygen Plants
SPECIFICATIONS
Advanced Performance, Ready for Innovation
Cryogenic Oxygen Plant - COP 30
Production Rate
≥30 liters/day
Compressed Air Requirement
Built-in Internal Compressor
Purity
≥90 %
Electrical Rating
380-415 V (±10%) @50Hz V3~
480 V (±10%) @60Hz V3~
Storage Capacity
60-80 liters
Reccomended Circuit Breaker
25 A, C-Type
Power Consumption
3.6-4.8 kW @50Hz
4.6-5.6 kW @60Hz
Noise Level
≤65 dBA
Operating Pressure
2 bar
Dimensions (W x L x H)
765 x 1340 x 1380 mm
Cooling Water Flow Rate
4-9 L/min
Weight
250 Kg
Liquid Oxygen Generator
Cryogenic Oxygen Plant - COP 40
Production Rate
≥40 liters/day
Compressed Air Requirement
Built-in Internal Compressor
Purity
≥90 %
Electrical Rating
380-415 V (±10%) @50Hz V3~
480 V (±10%) @60Hz V3~
Storage Capacity
80 liters
120 liters
160 liters
Reccomended Circuit Breaker
25 A, C-Type
Power Consumption
3.6-4.8 kW @50Hz
4.6-5.6 kW @60Hz
Noise Level
≤65 dBA
Operating Pressure
2 bar
Dimensions (W x L x H)
765 x 1340 x 1380 mm
825 x 1350 x 1380 mm
870 x 1667 x 1380 mm
Cooling Water Flow Rate
4-9 L/min
Weight
250 Kg
300 kg
Cryogenic Oxygen Plant - COP 60
Production Rate
≥58 liters/day (≥81.2 kg/day)
Compressed Air Requirement
Built-in Internal Compressor
Purity
≥90 %
Electrical Rating
380-415 V (±10%) @50Hz V3~
480 V (±10%) @60Hz V3~
Storage Capacity
120 – 160 liters
Reccomended Circuit Breaker
25 A, C-Type
Power Consumption
6.6-6.9 kW @50Hz
7.5-7.8 kW @60Hz
Noise Level
≤65 dBA
Operating Pressure
2 bar
Dimensions (W x L x H)
825 x 1350 x 1380 mm
Cooling Water Flow Rate
6-9 L/min.
Weight
400 kg